Food production depends on doing the same thing the same way, batch after batch. Motor power is one of the simplest ways to prove it: it tracks how a mixer, pump or conveyor is working in real time, from a sensor in the control cabinet that never touches the product or the washdown area.

Mixers and batch consistency

As a dough, cream, sauce or filling develops, its viscosity changes and so does the power the mixer needs. A good batch produces a consistent power curve, so comparing each batch with a reference curve catches problems such as a wrong ingredient, a missed addition or a temperature drift while the batch can still be saved. The same curve shows the end point: in a Load Controls trial on an ice cream mixer, power rose 15% through the run, three times more than current, then fell sharply when the product was ready.

Energy per batch

For products such as dough, the total energy put into the mix affects the result. Integrating motor power over the batch gives the energy input in kWh, which can be used to standardise mixing and to cost each product more accurately.

Pumps, conveyors and agitators

  • Pumps: a low trip point catches dry running and loss of prime on product and CIP pumps, a high trip point catches blockages. See monitoring and protecting pumps.
  • Conveyors: fast controls stop a jammed conveyor in 25 milliseconds, and long periods at no-load power show where lines run empty and waste energy.
  • Agitators: a sudden drop in power reveals a broken or detached blade without opening the vessel.
  • High-viscosity processes: power warns when a product is thickening beyond what the motor and gearbox should handle, before the motor burns out.

Hygienic by design

Because the sensors measure the motor supply, they are installed in the motor control cabinet. There are no penetrations in vessels or pipework, nothing to clean or validate in the product zone, and the electronics are protected from moisture and washdown.

Recommended products

Further reading: Agitators and mixers: profiling a process, Conveyors: jam detection, Why measure power, not amps

Frequently asked questions

Does anything touch the product?

No. The sensors measure the motor supply in the control cabinet, so nothing is installed in vessels, pipework or the washdown area.

Can motor power show when a mix is finished?

Often, yes. Many products show a clear change in mixer power at the end point, for example a sharp drop as the mix breaks down or a plateau when it is fully developed. Recording the curve for a good batch lets you detect it automatically.

Can I measure the energy used per batch?

Yes. The analogue power signal can be integrated in your PLC or recorder to give kWh per batch, which helps standardise mixing and cost each product.

Will it protect pumps on CIP and product lines?

Yes. The PMP-25 trips on the drop in power when a pump runs dry and on the rise when it is blocked.

Industry application image

Key applications

  • Mixer batch consistency and end point
  • Dough development and energy per batch
  • Viscosity and infeed monitoring
  • Pump dry-run protection
  • Conveyor jam and empty-running detection
  • Broken agitator detection

Application Note: Sensing Viscosity Change by Measuring Power

How motor power sensing detects viscosity changes in food production, helping improve batch consistency and protect equipment.

View resource →

Application Note: Profiling a Process

Using mixer power curves to standardise batches and detect the end point.

View resource →

Need the right sensor for your motor?

Tell us the application, motor size and drive type. We will recommend a model and send you a quotation. 12-month warranty and support from our team in France.

Request a quoteBrowse products